Open Access


Read more
image01

Online Manuscript Submission


Read more
image01

Submitted Manuscript Trail


Read more
image01

Online Payment


Read more
image01

Online Subscription


Read more
image01

Email Alert



Read more
image01

Original Research Article | OPEN ACCESS

Microscopic imaging ellipsometry of submicron-scale bacterial cells

Mai Ibrahim Khaleel1-3, Yu-Da Chen1-3, Ching-Hang Chien1-3, Yia-Chung Chang1

1Research Center for Applied Sciences, Academia Sinica, Taipei, 11529; 2Nano Science and Technology Program, Taiwan International Graduate Program, Academia Sinica and National Tsing Hua University; 3Department of Engineering and System Science, National Tsing Hua University, Hsinchu, 30013, Taiwan.

For correspondence:-  Yia-Chung Chang   Email: yiachang@gate.sinica.edu.tw

Accepted: 23 October 2017        Published: 30 November 2017

Citation: Khaleel MI, Chen Y, Chien C, Chang Y. Microscopic imaging ellipsometry of submicron-scale bacterial cells. Trop J Pharm Res 2017; 16(11):2713-2725 doi: 10.4314/tjpr.v16i11.20

© 2017 The authors.
This is an Open Access article that uses a funding model which does not charge readers or their institutions for access and distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) and the Budapest Open Access Initiative (http://www.budapestopenaccessinitiative.org/read), which permit unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited..

Abstract

Purpose: To demonstrate the power of microscopic imaging ellipsometry (MIE) to identify submicron-scale bacterial cells and track their surface topology variation.
Methods: Microscopic imaging ellipsometry with rotating compensator configuration was used to measure the ellipsometric spectra for dried submicron-scale Streptococcus mutans cells cultured on gold (Au) film for wavelengths (λ) in the visible range (λ = 490 – 710) nm. The ellipsometry characteristic images, Psi (Ψ), Delta (Δ), p- and s- polarized reflectance (Ip and Is), and reflectance difference image (RDI) for a chain of two and four dried cells, were collected for a series of different objective planes (near the focal plane) for λ = 600nm.
Results: The results show that by adjusting the position of objective planes (POP) to achieve the best focus, it was possible to identify cells smaller than 1 µm and observe their diffraction patterns in Ψ and Δ images. It was observed that Δ spectra and images were particularly sensitive to POP, while Ψ spectra and images for dried S. mutans cells were rather insensitive to POP.
Conclusion: MIE is a sensitive non-optical technique that can be used to image biological systems without the need for labeling of molecules
 

Keywords: Objective plane, Imaging ellipsometry, Submicron-scale bacterial cells, Streptococcus mutans, Biosensing, Focal plane

Impact Factor
Thompson Reuters (ISI): 0.523 (2021)
H-5 index (Google Scholar): 39 (2021)

Article Tools

Share this article with



Article status: Free
Fulltext in PDF
Similar articles in Google
Similar article in this Journal:

Archives

2024; 23: 
1,   2,   3,   4
2023; 22: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2022; 21: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2021; 20: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2020; 19: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2019; 18: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2018; 17: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2017; 16: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2016; 15: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2015; 14: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2014; 13: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2013; 12: 
1,   2,   3,   4,   5,   6
2012; 11: 
1,   2,   3,   4,   5,   6
2011; 10: 
1,   2,   3,   4,   5,   6
2010; 9: 
1,   2,   3,   4,   5,   6
2009; 8: 
1,   2,   3,   4,   5,   6
2008; 7: 
1,   2,   3,   4
2007; 6: 
1,   2,   3,   4
2006; 5: 
1,   2
2005; 4: 
1,   2
2004; 3: 
1
2003; 2: 
1,   2
2002; 1: 
1,   2

News Updates